Model: TD-30T-SHS-218  

 

Model TD-30T-SHS-218 is a high speed, TTL logic output threshold detector designed to operate from 2.0 to 18.0GHz.  This detector has a propagation delay of 15ns maximum

Quick Links: (click the links below for additional information)

Product Feature

Test Report
Unit Data

  PM612695

  PL9944-PL9946

  PL16395

 

 

Specifications:

Frequency Range 2.0 to 18.0 GHz (Usable down to 0.5 GHz)
VSWR Input 3.0:1 max @ -20 dBm - Measured 2.90:1
Minimum Signal Level for Logic 1 -20 dBm @ 2.0 GHz - Measured -21.3 dBm @ 2.0 GHz
-17 dBm @ 18.0 GHz -
Measured -22.1 dBm @ 18.0 GHz
Threshold Variation over Frequency
(Any 1.0GHz Window)
+/-0.5 dB - Measured +/-0.48 dB
Minimum Signal Level for Logic 0 -25 dBm - Measured -24.8 dBm
Dynamic Range +10 dBm max - Measured +10 dBm

Propagation Delay

(From 50% of an Input of -20 dBm)

15 nS max
Propagation Delay
(Ffrom 50% f an Input of +10 dBm)
15 nS max
DC Power Supply +/-15 V @ 100 mA max - Measured +15 V @ 56.7 mA, -15 V @
VSWR Input 3.0:1 @ -20 dBm
Size 2.2 " x 1.5 " x 0.4"
Weight < 3 oz
Finish Gold Plated

Environmental Ratings:

Temperature:  -55ºC to +85 ºC Operating
 -65 ºC to +125 ºC Non-Operating
 Humidity:  MIL-STD-202F, Method 103B Cond. B
 Shock:  MIL-STD-202F, Method 213B Cond. B
 Vibration:  MIL-STD-202F, Method 204D Cond. B
 Altitude:  MIL-STD-202F, Method 105C Cond. B
 Temperature Cycle:  MIL-STD-202F, Method 107D Cond. A