ERDLVA-1G18G-70-50MV-CW Preliminary

CW immune Extend Dynamic Range Detector Log Video Amplifier (ERDLVA)

Quantic PMI Model No. ERDLVA-1G18G-70-50-MV-CW is a CW immune Extend Dynamic Range Detector Log Video Amplifier (ERDLVA) that operates from 1.2 to 18 GHz.

Product Specifications

General Parameters:
Type: DLVA
Status: Preliminary
Frequency Range: 1.2 to 18 GHz
Frequency Min: 1.2 GHz
Frequency Max: 18 GHz
TSS: -72 dBm Min
TSS (Measured): -72 dBm Min
Size: 2.95" x 2.90" x 0.50"
Log Slope: 50 mV/dB ±5% over -60 to 0 dBm
Log Range: -65 to 5 dBm Min
Log Linearity: ±1.75 dB Max at any frequency
Rise Time: 20 ns Typ, 35 ns Max 10% to 90% of video output, fall time to 150 mV below peak <50 ns
Fall Time: 20 ns Typ, 35 ns Max 10% to 90% of video output, fall time to 150 mV below peak <50 ns
Recovery Time: 300 ns Typ, 500 ns Max to within 1 dB of small signal gain
Settling Time: 45 ns Max to within 1 dB final value, overshoot and ringing <50 mV from the final value
Finish: Nickel Plate
Frequency Flatness: ±2 dB Typ, ±2.5 dB Max
VSWR: 2.0:1 Max referenced to 50 Ohm
Weight: 6 oz Max
CW Immunity: -70 to -35 dBm
Pulse Range: 50 ns to 150 µs
Dynamic Range: -65 to 5 dBm Min
Video Output: 0 to +4 V Max into 91 Ohm min load
Leakage Level: -60 at 0 dBm input and video terminated in 100 Ohm
Environmental Ratings:
Operating Temperature: -54 ºC to +85 ºC
Non-Operating Temperature: -54 ºC to +85 ºC
Humidity: To 100% relative humidity +30°C to +55°C with condensation
Shock: 30G (6shocks oer axis, 6-9mS duration)
Vibration: MIL-STD-810F, Method 514.5 catergory 8
Altitude: 30,000FT operating, 40,000FT Non-Operating, MIL-STD-810D, Method 500.2 procedure 1 & 2