General Parameters: |
Type: | DLVA |
Status: | Active |
Frequency Range: | 2.0 to 18.0 GHz |
Frequency Min: | 2 GHz |
Frequency Max: | 18 GHz |
TSS: | -40 dBm Min |
TSS (Measured): | -40 dBm Min @ -40 ºC to +85 ºC (Video In) - Measured -43 dBm |
Size: | 2.50" x 1.50" x 0.44" |
Log Linearity: | ±0.5 dB Max @ +25 ºC - Measured +0.37 / -0.40 dB, ±0.75 dB Max @ +40 ºC to +85 ºC - Measured +0.51 / -0.73 dB @ -40 °C, +0.31 / -0.44 dB @ +85 °C |
Rise Time: | 30 ns Max (10% to 90%) - Measured 18.762 ns |
Fall Time: | 500 ns Max (@ Pulse width 100 µs Input) (90% to 10%) - Measured 105.785 ns |
Power Supply: | +12 VDC ±1 VDC @ 125 mA Max - Measured +98 mA, -12 VDC ±1 VDC @ 75 mA Max - Measured -48 mA |
Frequency Flatness: | ±1.65 dB Max - Measured ±0.45 dB |
VSWR: | 3.0:1 Max @ +23 dBm - Measured 1.719:1 |
Maximum Input Power(CW): | +23 dBm |
Duty Cycle: | 100% |
Propagation Delay: | 60 ns Max - Measured 21.99 ns |
DC Offset: | +95 mV +55/-100 mV @ +40 ºC to +85 ºC - Measured +83 mV |
Environmental Ratings: |
Operating Temperature: | -40 ºC to +85 ºC |
Non-Operating Temperature: | -57 ºC to +85 ºC |
Humidity: | 90% to 98% RH MIL-STD-202F, Method 106 |
Shock: | 30G, MIL-STD-202F, Method 213B Cond. C |
Vibration: | 10 to 55Hz (0.06DA), 55 to 2000Hz (10G) MIL-STD-202F, Method 204 Cond. C |
Altitude: | 20,000 Feet, MIL-STD-202F, method 105 |