SDLVA-0R81R6-75-CD-3 Preliminary

PMI Model No. SDLVA-0R81R6-75-CD-3 is a Successive Detection Log Video Amplifier (SDLVA) that operates between the 850 to 1550MHz frequency range. It has a dynamic range of 75dB, a log slope of 40mV/dB and a nominal video bandwidth of 20MHz. Furthermore, it has been designed using cutting edge GaAs technology which provides stunning performance and reliability in a compact package making it an optimum solution for high speed channelized receiver applications.

Product Specifications

General Parameters:
Type: SDLVA
Status: Preliminary
Frequency Range: 0.85 to 1.5 GHz
Frequency Min: 0.85 GHz
Frequency Max: 1.5 GHz
TSS: -70 dBm typ.
Size: 3.75" x 1.50" x 0.50"
Log Slope: 40 mV/dB nominal
Log Range: -70dBm to +5dBm
Log Linearity: ±0.8dB typ, ±1.2dB max @ (-60dBm to 0dBm), ±1.2dB typ, ±1.5dB max @ (-65dBm to +5dBm)
Rise Time: 15nsec typ., 25nsec max.
Fall Time: 15nsec typ., 30nsec max.
Settling Time: 40nsec max.
Finish: Gold Plated
VSWR: 1.5:1 typ- 1.8:1 max
VSWR (Measured): 1.5:1 typ- 1.8:1 max
Propagation Delay: 10 nS Maximum, 7 nS Typical
DC Offset: Log Video Output Slope
Dynamic Range: >75dB
Input Power: +10dBm CW
Limited IF Output: +5dBm Typical
Log Video Output Coupling: DC
Log Video Load: 50 Ohms ±10%
Log Slope Variation with Temperature: ±1 mV Typical
Log Slope Variation with Frequency: ±0.5 mV/dB Typ. (Over 80 MHz RF Bandwidth)
Tangential Sensitivity: -70dBm Typical
Environmental Ratings:
Operating Temperature: -55ºC to +85 ºC Operating
Non-Operating Temperature: -65 ºC to +100 ºC Non-Operating
Temperature Cycle: MIL-STD-202F, Method 107D Cond. A
Humidity: MIL-STD-202F, Method 103B Cond. B
Shock: MIL-STD-202F, Method 213B Cond. B
Vibration: MIL-STD-202F, Method 204D Cond. B
Altitude: MIL-STD-202F, Method 105C Cond. B