SDLVA-2D5G4D9G-45-55MV

PMI Model No. SDLVA-2D5G4D9G-45-55MV is a Successive Detection Log Video Amplifier operating over the 2.5 to 4.9 GHz frequency range.

Product Specifications

General Parameters:
Status: Preliminary
Frequency Range: 2.5 to 4.9 GHz
VSWR: 2.0:1
VSWR (Measured): 2.0:1 at J1 and J2 (50 Ohms ±2 nominal) - Measured 1.354:1 In- 1.178:1 Out
Log Slope: 55.5 ±5% mV/dB - Measured 54.9 to 55.4 mV/dB
PSAT: +15 dBm RF Output Max
Input Power: +20 dBm CW max.
RF Gain: 53 ±3 dB over all conditions
Frequency Flatness: <4.0 dB @ -55 to -45 dBm input, <6.0 dB @ -45 to -10 dBm input
Tangential Sensitivity: -70 dBm min. (J3)
Dynamic Range: -55 to -10 dBm
Video Log Linearity: +1.5 dB max over input dynamic range - Measured +0.6/-0.56 dB
Log Video Load: 50 ±5 Ohms
Recovery Time: 50 ns (90 to 10%)
Pulse Range: 100ns to CW
Duty Cycle: 0 to 100%
Rise Time: 20 ns (10 to 90%)
Power Supply: +15 VDC ±3%, 200 mV P-P Ripple @ 500 mA max. - Measured +430 mA -15 VDC ±3%, 200 mV P-P Ripple @ 180 mA max. - Measured -70 mA
Weight: 1.4 oz max
Environmental Ratings:
Operating Temperature: -20 ºC to +85 ºC
Non-Operating Temperature: -65 ºC to +95 ºC
Humidity: MIL-STD-202F, Method 103B Cond. A
Shock: MIL-STD-202F, Method 213B Cond. J
Altitude: -1300 to +35,000 FT Per, MIL-STD-202F Method 105C
Fungus: MIL-STD-810C, Method 508.2
Salt Fog: MIL-STD-202F, Method 101D Cond. B