Model: PSD-2G6G-CD-1 

PMI Model No. PSD-2G6G-CD-1 is High Power, Switch Box Assembly that provides protection to front-end receivers when in the presence of high power signals.  This is accomplished by sensing the input signal level and then switching the input signal into 50 ohms terminations when a set threshold level is exceeded.  This assembly operates from 2.0 to 6.0 GHz and can handle input power levels up to 10 Watts CW.  The unit is supplied with an external 0 to 69 dB step attenuator that can be used to adjust the signal levels feeding the internal threshold detector and thereby setting the trigger level of when the unit passes the input RF signal to the output of the switch assembly or when the signal is switched into the internal 50 ohms terminations.  The switching speed is 50 ns maximum.  This unit operates on 110 VDC, 50/60 Hz and is supplied in a housing that measures 15.0” x 10.0” x 4.0”.  This unit is ruggedized and designed for harsh environments and is EMI shielded.

Quick Links: (click the links below for additional information)

Product Feature

Test Report

 

Specifications:

Final Assembly:
   Frequency Response 2.0 to 6.0 GHz
   Power 110 VAC Only, 50/60 Hz
   Size 15.0" x 10.0" x 4.0"
   Finish Painted Gray
   Weight 20 lbs Typ
Pin Diode Switch:
   Power Handling >= 10 W
   Frequency Response   2.0 to 6.0 GHz
   Switching Speed < 50 ns
Threshold Detector:
   Frequency Repsonse 2.0 to 6.0 GHz
   Switching Speed < 50ns
   Output Type TTL (Compatible with Pin Switch)
   Sensitivity < -40 dBm
   Max Power (No Damage) 10 dBm
Coupler:
   Power Handling >= 10 W
   Frequency Response 2.0 to 6.0 GHz
   Coupling Factor 20 dB
50 Ohm LOAD:
   Power Handling >= 10 W
   Frequency Response 2.0 to 6.0 GHz
Attenuator:
   Power Handling > 2 W
   Frequency Response 2.0 to 6.0 GHz
   Attenuation 0 - 69 By (1) Front Panel Knob or Thumb Wheel

Environmental Ratings:

Temperature:  -35 ºC to +85 ºC Operating
 -40 ºC to +85 ºC Non-Operating
 Humidity:  MIL-STD-202F, Method 103B Cond. B
 Shock:  MIL-STD-202F, Method 213B Cond. B
 Vibration:  MIL-STD-202F, Method 204D Cond. B
 Altitude:  MIL-STD-202F, Method 105C Cond. B
 Temperature Cycle:  MIL-STD-202F, Method 107D Cond. A