SDLVA-500M4G-CD-1 *

Successive Detection Log Video Amplifier

Buy Now

PMI Model SDLVA-500M4G-CD-1 Successive Detection Log Video Amplifier (SDLVA) offers 70 dB Dynamic Range over the frequency range of 0.5 to 4.0 GHz. This model offers an ultra-fast rise time of 10nsec maximum, a recovery time of less than 60nsec and a limited RF Output of +7 dBm. The unit is temperature compensated such that log linearity over temperature remains less than ±2.5 dB over the full operating temperature range of -40 to +70 °C. This model is supplied in a compact housing measuring only 3.2" x 1.8" x 0.4". [Optional frequency ranges covering 100 MHz to 26.5 GHz are available.]

Product Specifications

General Parameters:
Status: Active
Frequency Range: 0.5 to 4.0 GHz
Frequency Min: 0.5 GHz
Frequency Max: 4 GHz
VSWR: 2.0:1
VSWR (Measured): 2.0:1 - Measured 1.70:1
Size: 3.2" x 1.8" x 0.4
Log Slope: 25 mV/dB Typ 50 Ohm Load - Measured 24.7 mV/dB
TSS: -73 dB Typ., -71 dB Max - Measured -73 dBm
Logging Range: -70 to 0 dBm - Measured -70 to 0 dBm
Input Power: +17 dBm Typ - Measured +17 dBm CW Max
RF Gain: 55 dB Typ
Dynamic Range: -70 to 0 dBm
Log Linearity: ±2.5 dB (-40 ºC to +75 ºC) - Measured ±0.9 dB
Video Flatness Over Frequency: ±50 mV Max
Recovery Time: 60 ns (40 ns Typ) - Measured 55 ns
Pulse Range: 30 ns to CW - Measured 30 ns to CW
Rise Time: 10 ns (5 ns Typ) - Measured 9.1 ns
DC Offset: 50 ± 50 mV
Power Supply: +15 V or +12 V @ 350 mA Nom -
Measured +15 VDC @ 271 mA
-15 V or -12 V @ 180 mA Nom -
Measured -15 VDC @ 93 mA
Connector: SMA (F)
Environmental Ratings:
Operating Temperature: -40 ºC to +75 ºC
Non-Operating Temperature: -65 ºC to +125 ºC
Humidity: MIL-STD-202F, Method 103B Cond. B
Shock: MIL-STD-202F, Method 213B Cond. B
Vibration: MIL-STD-202F, Method 204D Cond. B
Altitude: MIL-STD-202F, Method 105C Cond. B
Temperature Cycle: MIL-STD-202F, Method 107
Fungus: MIL-STD-810C, Method 508.2
Salt Fog: MIL-STD-202F, Method 107D Cond. A
SourceIn StockPurchase