PMI Model PLVA-218-50-618 is a 50dB Detector Log Video Amplifier designed to operate over the 2.0 to 18.0GHz frequency range, but is optimized for the 6.0 to 18.0GHz frequency range. It employs planar diode detectors and integrated video circuitry for high speed performance and outstanding reliability. It is of superior construction using state-of-the-art MIC/MMIC technology.

Product Specifications

General Parameters:
Status: Active
Frequency Range: 6.0 to 18.0 GHz
Frequency Min: 6 GHz
Frequency Max: 18 GHz
TSS: -40 dBm min.
Size: 2.20" x 1.50" x 0.40"
Log Slope: 50 mV/dB - Measured 50.6 mV/dB
Log Range: -40 dBm to +0 dBm (Useful Range up to +5 dBm)
Log Linearity: ±1.0 dB max. - Measured ±0.39 dB
Rise Time: 20 ns max. - Measured 10.4 ns
Recovery Time: 150 ns typ., 300 ns max. Measured 110 ns
Settling Time: 45 ns max. - Measured 31 ns
Power Supply: +15 V @ 75 mA - Measured 40 mA, -15 V @ 75 mA - Measured 40 mA
Frequency Flatness: ±1.0 dB - Measured ±0.8 dB
VSWR: 3.0:1 max. - Measured 2.45:1
Maximum Input Power(CW): +15 dBm CW max.
Log Slope Accuracy: ±4% of Average Slope
Temperature Stability: ±4% of Average Slope Measured ±0.9 dB
Pulse Range: 50 ns to CW
Video Output Level: 0 to 2.5 V (50 Ohms minimum load)
TSS (Measured): -40 dBm min. - Measured -42 dBm
Environmental Ratings:
Operating Temperature: -54ºC to +85 ºC
Non-Operating Temperature: -65 ºC to +100 ºC
Humidity: MIL-STD-202F, Method 103B Cond. B
Shock: MIL-STD-202F, Method 213B Cond. B
Vibration: MIL-STD-202F, Method 204D Cond. B
Altitude: MIL-STD-202F, Method 105C Cond. B
Temperature Cycle: MIL-STD-202F, Method 107D Cond. A