MARPS-30M6G-3U-1 Active

Multiagent Radio Frequency Path Simulator

Buy Now

Quantic PMI Model No. MARPS-30M6G-3U-1 is a Multiagent Radio Frequency Path Simulator consisting of an integrated amplified attenuator assembly and an 8-Way Amplified Power Divider that operate over the 30 MHz to 6.0 GHz frequency range in order to simulate field testing in a reduced, controlled lab environment.

Product Specifications

General Parameters:
Status: Active
Product Description: Quantic PMI Model No. MARPS-30M6G-3U-1 is a Multiagent Radio Frequency Path Simulator consisting of an integrated amplified attenuator assembly and an 8-Way Amplified Power Divider that operate over the 30 MHz to 6.0 GHz frequency range in order to simulate field testing in a reduced, controlled lab environment.
Item No.: 61
Insertion Loss: -4.0 dB Min, -4.5 dB Min Measured
-8.0 dB Max, -7.4 dB Max Measured
Gain (Input 9 to Output 1): -5 dB Min, -2.6 dB Min Measured
0 dB Nom, 0.5 dB Nom Measured
5 dB Max, 3.7 dB Max Measured
External +5 VDC Supply Via 78-Pin Connectors: +5 VDC /8A
Gain (Inputs 1 Thru 8 to Output 1): 4.0 dB Min, 6.1 dB Min Measured
10.0 dB Nom, 8.06 dB Min Measured
12.0 dB Max, 10.06 dB Max Measured
Switching Speed: 50 µs Max, 29.5 µs Measured
Insertion Loss
(Input 10 to Outputs 2 Thru 9):
-4.0 dB Min, -4.5 dB Min Measured
-8.0 dB Max, -7.4 dB Max Measured
Isolation
(Between Inputs 1 Thru 9):
-29.0 dB Min
-36.0 dB Nom, -32.03 dB Measured
Isolation
(Output 1 to Inputs 1 Thru 8):
-100.0 dB Min,
-104.0 dB Nom, -105 dB Measured
Isolation
(Output 1 to Input 9):
-48.0 dB Typ, -72 dB Min Measured
Isolation
(Outputs 2 Thru 9 to Input 10):
-32.0 dB Min
-36.0 dB Nom, -42 dB Measured
Attenuation Range
(Inputs 1 Thru 8 to Output 1):
127.5 dB, 124.3 dB Measured
Attenuation Flatness
(Inputs 1 Thru 8 to Output 1):
±1.0 dB @ 10 dB, ±0.5 dB Measured,br/>±1.5 dB @ 20 dB, ±0.6 dB Measured
±3.0 dB @ 40 dB, ±1.0 dB Measured
±5.0 dB @ 60 dB, ±2.3 dB Measured
Environmental Ratings:
Temperature: 0 ºC to +75 ºC (Operating) -50 ºC to +100 ºC (Storage)
Humidity: MIL-STD-202, Method 103B Cond. B
Shock: MIL-STD-202, Method 213B Cond. B
Altitude: MIL-STD-202, Method 105C Cond. B
Temperature Cycle: MIL-STD-202, Method 107D Cond. A
SourcePricePurchase