General Parameters: |
Status: | Active |
Frequency Min: | 2 GHz |
Frequency Max: | 18 GHz |
Threshold: | Fixed |
Detected Output Type: | TTL |
Size: | 1.5" x 1.5" x 0.5" |
Frequency Range: | 2 to 18 GHz |
VSWR: | 2.75:1 (2-18 GHz) - Measured 1.6:1 |
Weight: | 2.0 Oz |
Power Supply: | +15V @ 250 mA Max - Measured 132 mA |
RF Connectors: | The input signal connector shall be an SMA female in accordance with MIL-C-39012. The output signal connection shall be a solderable pin (ø 0.023" Minimum) with a ground lug next to it. |
Threshold Level: | Internally fixed to provide a minimum signal level of -30 ± 1.5 dBm at 6 GHz |
Threshold Setting Stability: | ± 3.0 dB over the operating temperature and frequency range - Measured 1.3 dB |
Detected Output: | The detected output signal shall be a TTL level high when the RF signal applied to the RF input exceeds the threshold level.Any signals below the threshold level shall result in an output level of TTL low (0). The TTL output shall be buffered in such that output loading has no effect on detector response. The detected output shall have a drive capacity of at least two standard TTL loads. |
Maximum RF Input: | +10 dBm (without damage) |
Input Operating Range: | -32 to -10 dBm (2-18 GHz) |
Response Time: | For any RF input greater than 3 dB above threshold, the maximum turn on response time measured at 90% RF to a TTL "1" output shall be 100 ns. The maximum turn off response time measured at 10% RF to a TTL "0" shall be 100 ns. |
Environmental Ratings: |
Operating Temperature: | -55 ºC to +85 ºC |
Non-Operating Temperature: | -65 ºC to +125 ºC |
Humidity: | MIL-STD-202F, Method 103B Cond. B |
Shock: | MIL-STD-202F, Method 213B Cond. B |
Vibration: | MIL-STD-202F, Method 204D Cond. B |
Altitude: | MIL-STD-202F, Method 105C Cond. B |
Temperature Cycle: | MIL-STD-202F, Method 107D Cond. A |