General Parameters: |
Status: | Active |
Type: | 8-Way |
Frequency Min: | DC |
Frequency Max: | 23.0 GHz |
Isolation: | 22 to 23 GHz - 10 dB Typ. 18 to 22 GHz - 15 dB Typ. 8 to 18 GHz - 20 dB Typ 2 to 8 GHz - 20 dB Typ. 1 to 2 GHz - 10 dB Typ . 0.5 to 1 GHz - 10 dB Typ. 100 to 500 MHz - 5.dB Typ. 40 to 100 MHz - 7 dB Typ. 10 to 40 MHz - 12 dB Typ. |
Insertion Loss: | 22 to 23 GHz - 7.0 dB Max. 18 to 22 GHz - 5.0 dB Max. 8 to 18 GHz - 3.2 dB Max. 2 to 8 GHz - 2.0 dB Max. 1 to 2 GHz - 2.0 dB Max. 0.5 to 1 GHz - 2.0 dB Max. 300 to 500 MHz - 1.5 dB Max. 200 to 300 MHz - 2.6 dB Max. 100 to 200 MHz - 3.2 dB Max. 80 to 100 MHz - 4.0 dB Max. 20 to 80 MHz -4.5 dB Max. 10 to 20 MHz - 5.0 dB Max. |
Frequency Range: | DC to 23.0 GHz |
Amplitude Balance: | 22 to 23 GHz - ± 2 dB Max. 18 to 22 GHz - ± 1.2 dB Max. 8 to 18 GHz - ± 0.5 dB Max. 2 to 8 GHz - ± 0.3 dB Max. 1 to 2 GHz - ± 0.5 dB Max. 0.5 to 1 GHz - ± 0.5 dB Max. 10 to 500 MHz - ± 0.5.dB Max |
Phase Balance: | 22 to 23 GHz - 20° Max 18 to 22 GHz - 15° Max. 8 to 18 GHz - 10° Max. 2 to 8 GHz - 4° Max. 1 to 2 GHz - 3° Max. 0.5 to 1 GHz - 5° Max. 10 to 500 MHz - 5° Max |
Average Power Into Load VSWR: | 25 Watts |
Connectors: | 2.92 mm FEMALE REMOVABLE |
Finish: | Painted Blue |
Size: | 5.00" X 3.70" X 0.43" |
VSWR Input: | 22 to 23 GHz - 2.0:1 Typ. 18 to 22 GHz - 2.0:1 Typ. 8 to 18 GHz - 2.0:1 Max. 2 to 8 GHz - 2.1:1 Max. 1 to 2 GHz - 2.4:1 Max. 0.5 to 1 GHz - 2.3:1 Typ. 300 to 500 MHz - 4.0:1 Typ. 200 to 300 MHz - 5.0:1 Typ. 100 to 200 MHz - 6.0:1 Typ. 10 to 100 MHz - 7.0:1 Typ. |
VSWR Output: | 22 to 23 GHz -2.0:1 Typ. 8 to 22 GHz - 2.0:1 Typ. 8 to 18 GHz - 2.0:1 Max. 2 to 8 GHz - 2.1:1 Max. 1 to 2 GHz - 2.6:1 Max. 0.5 to 1 GHz - 2.5:1 Typ. 300 to 500 MHz - 2.0:1 Typ. 200 to 300 MHz - 2.5:1 Typ. 100 to 200 MHz - 3.0:1 Typ. 80 to 100 MHz - 4.0:1 Typ. 10 to 80 MHz - 7.0:1 Typ. |
Environmental Ratings: |
Operating Temperature: | -55 °C TO +85 °C |
Non-Operating Temperature: | -65 °C TO +125 °C |
Humidity: | MIL-STD-202, METHOD 103B COND. B |
Shock: | MIL-STD-202, METHOD 213B COND. B |
Vibration: | MIL-STD-202, METHOD 204D COND. B |
Altitude: | MIL-STD-202, METHOD 105C COND. B |
Temperature Cycle: | MIL-STD-202, METHOD 107D COND. A |