PMI Model PL-MUX-2G18G-LM-AMP-SP4T-SFF is an integrated module containing a multiplexer with 4 bands covering 2 to 18 GHz. Each band is followed by a limiter and amplifier to give a gain of 23 dB. The output is a 4 way switch selecting one of the four bands.
| General Parameters: | |
|---|---|
| Status: | Preliminary |
| Product Description: | PMI Model PL-MUX-2G18G-LM-AMP-SP4T-SFF is an integrated module containing a multiplexer with 4 bands covering 2 to 18 GHz. Each band is followed by a limiter and amplifier to give a gain of 23 dB. The output is a 4 way switch selecting one of the four bands. |
| Item No.: | 57 |
| Frequency Range: | 2 to 18 GHz |
| Gain: | 23 ±1.5 dB |
| Maximum Input Power (Without Damage): | 1 W CW, 10 W Pulsed (1 µs pw at 1 kHz PRF) |
| Output 1 dB Compression: | ≥15 dBm |
| OIP3: | ≥20 dBm |
| Out of Band Rejection: | ≥60 dBc |
| Output Control: | 2 Bit TTL |
| Switching Time: | <10 µs |
| Filter Band 1: | 2 to 3.4 GHz |
| Filter Band 2: | 3.6 to 5.6 GHz |
| Filter Band 3: | 6.4 to 9.6 GHz |
| Filter Band 4: | 10.4 to 18 GHz |
| Noise Figure: | <5 dB |
| Power Supply: | +12 VDC at (TBD) mA |
| Connectors: | RF: SMA Female Control/Power: Micro D-Sub Male |
| Finish: | Gold Plated |
| Export Classification (ECCN): | EAR99 |
| Environmental Ratings: | |
| Temperature: | 0 °C +65 °C Operating -65 °C to +125 °C Non-Operating |
| Humidity: | MIL-STD-202F, Method 103B Cond. B |
| Shock: | MIL-STD-202F, Method 213B Cond. B |
| Altitude: | MIL-STD-202F, Method 105C Cond. B |
| Temperature Cycle: | MIL-STD-202F, Method 107D Cond. A |