General Parameters: |
Status: | Active |
Frequency Min: | 0.1 GHz |
Frequency Max: | 4.0 GHz |
Threshold: | Fixed |
Detected Output Type: | TTL |
Size: | 1.50" x 1.50" x 0.50" |
Weight: | 2.0 oz |
Finish: | Painted Gray |
Power Supply: | +15 VDC @ 250 mA Max |
Threshold Level: | Internally Fixed to provide a minimum signal level of -32 ± 1.5 dBm |
Threshold Setting Stability: | ±3.0 dB over the operating temperature and frequency range |
Detected Output: | The detected output signal shall be a TTL level high when the RF signal applied to the RF input exceeds the threshold level shall result in an output level of TTL low. The TTL output shall be buffered in such that output loading has no effect on detector response. The detected output shall have a drive capacity of at least two standard TTL loads. |
Frequency Flatness: | -32 dBm to -10 dBm |
Response Time: | For any RF input greater than 3 dB above threshold the maximum turn on response time measured at 90% RF to a TTL "1" Output shall be 100 nS the maximum turn off response time measured at 10% RF to a TTL "0" shall be 100 ns. |
Connectors: | The input signal connectors shall be an SMA female in accordance with MIL-C-39012. The output signal connection shall be a soderable pin (Ø0.023" Min). |
Input VSWR: | 2.75:1 |
Environmental Ratings: |
Operating Temperature: | -55 °C to +85 °C |
Non-Operating Temperature: | -65 °C to +125 °C |
Humidity: | MIL-STD-202F, Method 103B Condition B |
Shock: | MIL-STD-202F, Method 213B Condition B |
Vibration: | MIL-STD-202F, Method 204D Condition B |
Altitude: | MIL-STD-202F, Method 105C Condition B |